Alarm Verification Hong Chang :
Double check the fire alarm signal if is real to avoid false alarm. When receiving a fire alarm signal, panel will wait for 5~8 seconds before transmitting fire alarm.If panel receive a fire alarm signal at first time and receive the same signal again within 5~8 seconds, it will transmit. If not receive a fire alarm signal again within 5~8 seconds, it will cancel.
Battery self-protect:
If AC power cut, it will transfer automatically to use battery power. When battery is running lower 18VDC, it will stop discharging to avoid over discharge.
Indication LED:
Different color light to indicate different condition.
Green light: AC power normal.
Yellow and Red light: abnormal condition with alarm sound.
Circuit auto and manual test: Test circuit from 1 to last automatically or set a certain circuit manually to test.
Annunciator Panel is available.
Size :
5~15 zone 20~30 zone 35~60 zone 66~90 zone 95~100 zone
300(W) 410(H) 107(D) mm 370(W) 510(H) 150(D) mm
480(W) 720(H) 200(D) mm 480(W) 850(H) 200(D) mm
480(W) 1000(H) 220(D) mm
MANUAL PUSH BUTTON
Model No. HC-2W (IN DOOR)
HC-1W (OUT DOOR) Supply Voltage 24 VDC
Consumption Current 100 mA Joint Volume DC 30V 1uA
MANUAL BREAK GLASS
Model No. FIRE-01 Working Voltage 220VAC 50HZ 24VDC
Max. Current 5A 220VAC 50HZ 8A 24VDC
Contact Resistance < 0.1 Ω
Working Conditions temp. -10~+50°C
max. Relative humidity < 93 ± 2%
Ionization Smoke Detector
Model No. HC-202D
Supply Voltage 24VDC
Alarm Current 60mA
Standard Current 35 uA
Humidity 0-95% RH
Operating Temperature 0-50°C
Ionization Smoke + Heat Detector
Model No. HC-207D
Supply Voltage 12-24VDC
Alarm Current 60mA
Standard Current 0 uA
Humidity 0-95% RH
Operating Temperature 0-50°C
Photoelectric Smoke Detector
Model No. HC-206ER
Supply Voltage 24VDC
Alarm Current 30mA
Standard Current 60 uA
Humidity 0-95% RH
Operating Temperature 0-50°C
Rate of Rise Heat Detector
Model No.
HC-306A
Supply Voltage
24VDC
Alarm Current
60mA
Standard Current
0 uA
Humidity
0-95% RH
Operating Temperature
0-50°C
Fixed Temperature Heat Detector
Model No.
HC-407A
Supply Voltage
12 – 24VDC
Alarm Current
60mA
Standard Current
0 uA
Humidity
0-95% RH
Operating Temperature
0-50°C
Self-Contained Smoke Detector
Model No.
HC-208
Supply Voltage
9VDC (Battery)
Testing Ambient Tube
32° F to 120° F
Standard Current
90 uA
Type
IONIZATION
Remote Indicator Lamp
Motor Driven Type Alarm Bell
Model No.
HC-624B
Rated Voltage
24VDC
Rated Current
20mA
db@10ft
95
approval
UL, ULC, CE
Indicating Lamp
Model No.
HC-300L
Supply Voltage
24VDC
Current
100mA
Luminous Component
LED
Sound Light Fire Alarm Hong Chang
Dimension
135 x 115 x 48 mm
Temparature Range
-10 to +50° C
Humidity Range
0-95% RH
Supply Voltage
DC 12/24V
Working Current
80 – 180 mA
Operating Temperature
0 – 50°C