Jenis Control ACCESSORIES Fike Fm200
Berikut tipe dengan kodenya perlengkapan pemadam api Fike Fm200 :
MANUAL RELEASE SWITCH 10-1638
The Manual Release Switch is a dual actuation device which provides a means of manually discharging the automatic fire extinguishing system when used in conjunction with the Fike Control Panel. To operate the Manual Release Switch pull the spring clip safety pin (breaking the seal) and depress the button. The switch will remain engaged until released by unlocking the button with a key. A single normally open contact block is provided. The front housing of the Release Switch is constructed of stainless steel with the keyed red plastic release button centered and bordered in black trim. The dimensions of this component are 4-1/2″ wide, 4-9/16″ high and 2-3/8″ deep, and it may be mounted to a standard 4″ electrical box or others (reference Data Sheet 1031).
SYSTEM ABORT SWITCH 10-1639
The System Abort Switch is designed to be used in conjunction with other system equipment. It provides a temporary manual means be which the system actuation circuit may be interrupted, when operated prior to the circuit actuation. The unit employs a momentary contact push button switch. While depressed, the switch causes the agent release circuit to be manually delayed. Upon release of the Abort Switch, the release circuit will follow the specific configuration of the system control panel. The Abort Switch may be mounted to a standard 4″ electrical box or others (reference Data Sheet 1031).
MAIN-RESERVE SWITCH 10-1640
The “Main” to “Reserve” switch is used with systems that incorporate main and reserve (back-up) agent storage. The switch may utilize 1 or 2 Form “C” Contact blocks which will provide an electrical path to either the “Main” or “Reserve” releasing modules. Following a system discharge, reset any field devices. Once all devices are in a stand-by status the Main-Reserve Switch may be moved to the “Reserve” position. The Control Panel may then be reset to a normal mode for uninterrupted Fike protection. The empty “main” containers can be removed for recharge. After the containers in the “Main” system have been recharged, the switch may be returned to the “Main” position. The switch may be mounted to a standard 4″ electrical box or others (reference Data Sheet 1031).
https://www.youtube.com/watch?v=e_kUBHxeU2I&list=PLKjk9ZBOgJqtsbQCibR3XOXmQpgtxo2HP
KEYED ABORT SWITCH 10-1642
The System Abort Switch is designed to be used in conjunction with other system equipment. It provides a temporary manual means by which the actuation circuit may be interrupted before automatic actuation occurs. The unit employs a keyed contact switch with two positions, normal and abort. While in the extreme left hand position the Abort Switch is in the “normal” mode In the extreme right hand position the release circuit is manually delayed. The Keyed Abort Switch may be mounted to a standard 4″ electrical box or others (reference Data Sheet 1031). NOTE: Keyed abort is not recognized by approval/listing agencies.
KEYED REMOTE RESET 10-1641
The Keyed Remote Reset Switch provides a method for resetting the IntellaScan II from a remote location. To reset the Control Panel simply insert the key and turn in a clockwise direction. Upon release of the key the spring loaded switch will return to its original position The front housing of the Keyed Remote Reset Switch is constructed of stainless steel and is 4-1/2″ wide, 4-9/16″ high and 2-3/8″ deep. It may be mounted to a standard 4″ electrical box or others (reference Data Sheet 1031).
Jenis FM200 equipment Material Safety Data Sheet Fike Fm200
Berikut tipe dengan kodenya perlengkapan pemadam api Fike Fm200 :
AGENT STORAGE CONTAINERS WITH HFC-227EA
Fike Clean Agent Containers are used in fi re extinguishing systems to store the Clean Agent until a fi re develops and the agent must be released. The Clean Agent is retained in the container by a Impulse Valve assembly which contains a fast-acting rupture disc. The disc will be ruptured, and the Clean Agent released, through the operation of an actuator by an electric signal that is automatically, manually or pneumatically controlled.
Fike Clean Agent Containers have passed extensive testing by Factory Mutual and Underwriters Laboratory and are used in installations where 3 to 1045 pounds (2.0 to 474 kg) of HFC-227ea agent is required. Clean Agent containers can be fi lled in 1 pound (0.5 kg) increments to their maximum capacity.
HFC-227ea CLEAN AGENT
HFC-227ea provides superior fire protection in a wide range of applications from sensitive electrical equipment to industrial applications using flammable liquids. HFC-227ea is ideal for applications where clean-up of other media presents a problem, where weight versus suppression potential is a factor, where an electrically non-conductive medium is needed and where people compatibility is an overriding factor. When environmental impact is a consideration, HFC-227ea is particularly useful. It has zero ozone-depleting potential, low global warming potential and a short atmospheric lifetime. These characteristics make it suitable not only for new installations using Fike’s total flooding systems, but also for Halon 1301 replacement applications. HFC-227ea is an odorless, colorless, liquefied compressed gas. (See Physical Properties) Table for additional information). It is stored as a liquid and dispensed into the hazard as a colorless, electrically non-conductive vapor that is clear and does not obscure vision. It leaves no residue and has acceptable toxicity for use in occupied spaces at design concentration. HFC-227ea extinguishes a fire by a combination of chemical and physical mechanisms. HFC-227ea does not displace oxygen and therefore is safe for use in occupied spaces without fear of oxygen deprivation.
FIKE ENGINEERED NOZZLES FOR HFC-227ea CLEAN AGENT SYSTEMS
The function of the Fike Engineered Discharge Nozzle in a fire extinguishing system is to distribute the Clean Agent in a uniform, pre-determined pattern and concentration. The nozzles are designed to complete the discharge of Clean Agent in 10 seconds or less when installed within the design limitations of the Fike Design Manual and the Fike Flow Calculation computer program.
Fike Engineered Discharge Nozzles are available in sizes of 3/8” (10mm) through 2” (50mm). Each nozzle is available in 180 and 360 degree discharge patterns. The Discharge Nozzle size refers to the size of Schedule 40 or 80 steel pipe to which it can be connected. The nozzle discharge orifices are drilled perpendicular to the center line of the threads. The nozzles are mounted to allow the agent to be discharged on a horizontal axis. Nozzle orifices are available in a wide range of sizes to provide accurate clean agent flow results. All nozzles have been tested for their ability to discharge the clean agent under extreme conditions. Nozzle orifice drilling must be done at the Fike factory only after “As-Built” calculations of the installed piping system(s) have been performed, using the Fike Flow Calculation computer program. The Fike Discharge Nozzle used shall be Factory Mutual (FM) approved and Underwriters Laboratories (UL) listed.
IMPULSE VALVE OPERATOR (IVO) KIT
The Impulse Valve Operator (IVO) provides the means to electrically or manually activate the Fike Impulse Valve clean agent containers. Upon activation, a pin is extended with the force required to open the inverted rupture disc, allowing the agent to be released from the container. The IVO can be activated either manually by depressing the red button or electrically via a signal from the fi re suppression control panel. Once activated, the IVO can be reset using the included reset tool. Fike Clean Agent Containers with Impulse Valve use an Impulse Releasing Module (IRM) to supervise the agent release circuit wiring (for open and ground fault conditions) from the container to the control panel. Up to 6 IRM’s may be released from a single Fike fi re suppression control panel. An IVO kit is included when ordering an Impulse Valve clean agent container with electric actuation. The kit includes the following components:
CHECK VALVE
Check Valves are used prevent agent loss from the open end of a manifold and/or piping system in the event that one or more containers are removed for servicing / maintenance. Check Valves are required for multiple containers connected in a manifold arrangement and for containers used in a main / reserve system, without the need for redundant piping systems, to prevent agent loss and to ensure personnel safety if the system is operated when any containers are removed for maintenance
DISCHARGE PRESSURE SWITCH
Discharge Pressure Switch (p/n 02-12534) is used to provide a positive pneumatic confi rmation to the control system that the Fike Fire Suppression system has been discharged. When a system is discharged manually, the discharge pressure switch is required to provide the input to the control system needed to activate various audio/visual warning devices and auxiliary relays. The switch is operated pneumatically using the agent pressure in the discharge piping network. The unit has a single-pole, double-throw switch that can be wired for normally open or normally closed operation. The minimum pressure required to activate this switch is 40 psig (3 bar). Discharge Pressure Switch is installed in the 1/4” NPT (female threads) port machined into the Adapter Nipple as shown in the illustration below.
LOW PRESSURE SWITCH
Fike offers an optional Low Pressure Switch (LPS) for the purpose of continuously monitoring the container pressure for a low-pressure condition. If the pressure inside the container drops below 288 psig (1986 kPa), the switch contacts will transfer and invoke a “trouble” indication on the control panel. The LPS (P/N 02-12533) has a single pole, double-throw switch that can be wired for normally open or normally closed states. The LPS is an optional item for Impulse Valve containers. It may be ordered along with a confi gured Impulse Valve container or as a separate item. The design of the Impulse Valve allows a Low Pressure Switch to be installed on a fully pressurized container.
FIKE FM200 ALAT PEMADAM KEBAKARAN
Mengenai Perusahaan Alat Pemadam Api Merek Fike Fm200 :
Fike’s Fire Alarm Bells, manufactured by Gentex Corporation, provide durable and dependable operation required for life safety alarm systems. Alarm bells are low current, high decibel notification appliances for use in fire and burglary systems or other important signaling applications. The Fire Alarm Bells are available in 24VDC or lZOVAC, 6″ or 10″ housing and are can be used for indoor or outdoor applications. When used outdoors, Fike’s Back Box (P/ N 20423-125) is also required.
Fike Clean Agent Containers are used in fi re extinguishing systems to store the Clean Agent until a fi re develops and the agent must be released. The Clean Agent is retained in the container by a Impulse Valve assembly which contains a fast-acting rupture disc. The disc will be ruptured, and the Clean Agent released, through the operation of an actuator by an electric signal that is automatically, manually or pneumatically controlled. Fike Clean Agent Containers have passed extensive testing by Factory Mutual and Underwriters Laboratory and are used in installations where 3 to 1045 pounds (2.0 to 474 kg) of HFC-227ea agent is required. Clean Agent containers can be fi lled in 1 pound (0.5 kg) increments to their maximum capacity.
Fike Fm200 adalah Perusahaan yang mengeluarkan beberapa jenis Alat Pemadam Api :